Selection Guide

Supercapacitor Lifetime: How Temperature and Voltage Affect Longevity

How temperature and voltage drive supercapacitor aging, how end-of-life is defined, and how to estimate service life for high-temperature designs.

Updated 2026-10-28 · 9 min read

The challenge

Supercapacitors do not usually fail suddenly; they age — capacitance decreases and ESR increases. A design must still work at end of life.

How end of life is defined

Manufacturers typically define end of life as a capacitance loss (e.g. −20% or −30%) and/or ESR increase (e.g. 2× initial) after a load-life test at rated voltage and maximum temperature.

Temperature

A commonly cited approximation is that life roughly doubles for every 10 °C reduction in cell temperature. Cell temperature includes self-heating from ESR losses.

Voltage

Lower working voltage slows electrolyte degradation. Derating by a few hundred millivolts per cell can significantly extend life — quantify with the manufacturer’s data.

Estimating life (approximation)

L ≈ L_rated · 2^((T_rated − T_use)/10)

This is a first-order estimate only; it does not replace the manufacturer’s life curves or qualification testing.

Low-temperature operation

Cold reduces capacitance modestly and increases ESR significantly. For −40 °C operation, size ESR drop at the cold corner.

Need help applying this?

Send your load profile and our engineers will suggest suitable parts.

Recommended supercapacitor types

Winding-Type Supercapacitors

Cylindrical cells built from wound electrode foils — the workhorse format from a few farads to thousands.

Explore

Radial-Lead Supercapacitors

Through-hole cylindrical cells for PCB mounting, typically from about 0.5 F to around 100 F.

Explore

Supercapacitor Modules

Series/parallel assemblies with balancing, housed for system-level voltage and energy.