Supercapacitor Voltage Rating Guide: Choosing Working Voltage and Derating
How to choose supercapacitor rated voltage: 2.7V vs 3.0V cells, 5.5V parts, derating for life, surge voltage, and series cell counts.
Updated 2026-10-28 · 9 min read
The challenge
Voltage is the strongest lever on both energy (∝ V²) and lifetime. Running at the full rated voltage maximises energy but reduces life, especially when hot.
Rated, surge, and working voltage
Rated voltage: the maximum continuous voltage specified by the manufacturer.
Surge voltage: a short-term limit some datasheets specify — never design to it.
Working voltage: what your charger actually applies, including tolerance.
2.7 V vs 3.0 V cells
Cell
Energy at rating (relative)
Notes
2.7 V
1.00
Widely used, more life margin at equal working voltage
3.0 V
≈1.23
More energy per cell; check life at your temperature
Number of series cells
N = ceil( V_bus_max / V_cell_working )
Example: a 24 V bus with 10% overshoot is 26.4 V. At 2.5 V working per cell, N = ceil(10.56) = 11 cells.
Derating
Reducing working voltage by roughly 0.1–0.2 V per cell is a common way to extend life. Quantify the effect with the specific part’s life curves rather than general rules.
Need help applying this?
Send your load profile and our engineers will suggest suitable parts.