Data protection for SSDs, RAID controllers, and DC UPS ride-through.
Power requirements
Power-loss protection needs enough energy to flush caches and complete writes — typically tens of milliseconds to a few seconds. DC UPS systems may need seconds to ride through short outages.
Why supercapacitors fit
Supercapacitors deliver high current instantly and can be health-monitored by measuring capacitance and ESR in-circuit.
Selection factors
Flush energy and timing
Health-monitoring approach
Height and footprint on dense boards
Limitations
Long-duration UPS runtime still requires batteries
Supercapacitor types
EDLC Supercapacitors
Electric double-layer capacitors store charge electrostatically at the electrode–electrolyte interface.
Explore
Coin-Cell Supercapacitors
Low-profile button cells for RTC and memory hold-up where current is in the microamp range.
Explore
Radial-Lead Supercapacitors
Through-hole cylindrical cells for PCB mounting, typically from about 0.5 F to around 100 F.
Explore
5.5V Supercapacitors
Pre-assembled 5.5 V parts for direct use on 5 V and 3.3 V logic rails.
Explore
Sizing a supercapacitor for ups and memory backup?